Skip to menu

XEDITION

SM445 Preconfigured High Resolution CCD Spectrometer

SM445: Preconfigured High Resolution CCD Spectrometer

 

 

- Wide Spectral Range (Up to 200 - 1050nm)

- High Optical Resolution by 3K array CCD

- Extremely Low Light Exposure Time up to 10µsec

- Compact & Modular Design

 

The SM445 is a new compact design CCD Spectrometer for use with a PC. Based on SP's special optical bench design, it supports many different applications where spectral or color measurements are required, including high dynamic range applications. The SM445 can accept light directly through its built in slit or via optical fiber. The durable aluminum housing that encloses the SM445 provides stable optical bench operation over a wide range of temperatures. The standard sensor arrays used are the Toshiba TCD1304 for the SM445. The array driver electronics have been designed for highly sensitive yet stable operation. This array (in conjunction with our special UV coating process and customized order sorting filters) allows up to an 850nm measurement window from 200nm to 1050nm (smaller measurement window sizes increase spectral resolution and light sensitivity). Thanks to the more pixel numbers, the SM445 is preferable for the applications requiring higher resolution. Standard interface to the SM445 is a USB 1.1/2.0 compatible interface with 16 bit extended dynamic range. Our USB board can support multichannel configuration up to 8. With this multichannel configuration, a higher resolution for wide range or a dual spectrometer system (one for measurement and the other for reference) is possible. Spectral Products applies new UV enhancing coating on the CCD to increase the UV sensitivity below 450nm comparing with the conventional UV coating that is widely used in CCD spectrometers. By the help of this new UV coating, the signal sensitivity below 500nm can get improved ~20 50% more in general. Software support includes an SDK and DLLs for dedicated applications development and our SM32Pro Windows based spectral acquisition and analysis software.

Model

SM 445

Detector

Toshiba TDC 1304 CCD

Pixel: 3648 (effective)
Sensing Pixel size: 8µm x 200µm
Well depth: 100,000 e-

Spectral Resolution

0.10 to 10nm dependent on spectral range, slit width, fiber diameter

Spectral Range

200 - 1050nm

Spectrograph f#

2.7

Fiber Coupler

SMA 905 or FC standard

Stray Light

< 0.05% @632nm (< 0.1% avg)

Dark Noise RMS

< 50 RMS counts in 16-bit @35ms integration time

Signal to Noise Ratio

> 300 : 1

min. Integration Time

8msec (General Mode) / 10µsec (Shutter Mode)

Trigger mode

Free Run mode
Software Trigger mode
External Trigger mode

Orders Sorting Filter

Longpass filter or linear variable filter installed per wavelength coverage

Computer Interface

USB 1.1 / 2.0 16-bit (support up to 8 multi-channel configuration)

Software

Windows XP/VISTA/Win7(both 32/64bit)/Win10 (both 32/64bit)

SM32Pro included (free with spectrometer)
Includes DLL libraries and SDKs for easy custom application development

Dimensions (inches)

3.54H x 2.76W x 1.73D inches

Weight

0.88lbs

Slit Options

5, 10, 25, 50, 100, 200, 400um

Temperature Induced Shift

< 2 pixels per ± 15°C

Lower Thermal Expansion Option is available on request